Our Products

ELRA (Endo Luminal Radiofrequency Ablation) for treating biliary obstructions

For treating malignant biliary obstructions caused by
cholangiocarcinoma and pancreatic cancer.

Key features:

Temperature controlled - temperature sensing system to manage a consistent temperature of the ablation zone.

Prevention of over-application of energy with the specialised Viva Combo generator's impedance monitoring system.

Multiple lengths available according to the anatomy and size of the stricture - 11mm, 18mm, 22mm and 33mm.

Four ring and two ring electrodes available.


EUSRA (Endoscopic Ultrasound Radiofrequency Ablation)

For the treatment of pancreatic tumours

Key features:

Feasible and
safe ablative treatment for locally advanced unresectable pancreatic cancer,
neuroendocrine tumours, and cystic neoplasms.

Easy approach to target lesions with a great pushability of the needle.

Good echogenicity for safe procedure under EUS-guidance.

Inner cooling system to ablate large volumes of tumour without tissue charring.













Monopolar system.

19G Tip, lengths available 5mm, 7mm, 10mm, 15mm and 20mm


Fujifilm Arietta 850 FF Endoscopic Ultrasound System

Carving Imaging makes it possible to render clear Ultrasound images from the superficial to the very deepest areas of the abdomen. The ARIETTAâ„¢ 850 FF ENDO Diagnostic Ultrasound System is equipped with various diagnostic applications to support high level diagnosis. Applicable with EG-740UT, EG-580UT and EG-580UR.





Leinzett Portable Video Cholangioscope

The Leinzett video cholangioscope offers:

  • 6F, 4.8F and 3.6F working channels available.
  • 4 way and 2 way angulation.
  • High quality image - 160,000 pixels.
  • LED light source.
  • No fixed processor or trolley required.
  • No capital commitment.
  • Portable


TaeWoong Niti-S Double Oesophageal Stent

For malignant oesophageal strictures

The only fully covered stent with an uncovered outer sleeve to reduce migration, prevent tumour ingrowth and reduce the need for reintervention.

Key features:

Double layered design

A silicone full covering prevents the risk of tumour ingrowth
An additional uncovered outer mesh in the middle portion of the stent reduces migration

A retrieval string at the proximal end of the stent helps with repositioning

Radiopaque markers
Four at both ends & two in the middle


* Hussain et al, 2016 Double-layered covered stent for the treatment of malignant oesophageal obstructions: Systematic review and meta-analysis; â€‹
World J Gastroenterol 2016 September 14; 22(34): 7841-7850 â€‹
ISSN 1007-9327 (print) ISSN 2219-2840 (online) â€‹
© 2016 Baishideng Publishing Group Inc. All rights reserved. 

TaeWoong Niti-S Fully Covered Biliary Stent (Flare type)

For the the treatment of benign and/or malignant biliary strictures

  • The fully covered silicone body prevents tissue ingrowth.
  • Flares at both ends to prevent migration.
  • A proximal retrieval string helps for easy repositioning or removal.

Walz EHL (Electrohydraulic Lithotripsy) - a simple and effective method for large stone management

EHL - a simple and effective method for large
stone management

  • Highest
    efficiency compared to other technologies, short operation times
  • Stones are
    normally disintegrated with only a few shock waves
  • Security:
    shock waves destroy hard objects and treat soft tissue with care
  • Highly localised
    energy transfer compared to laser and extracorporal shock waves
  • Endoscope
    protection through rounded probe tips; no breaking problem compared to laser
    fibres
  • Controlled
    energy levels: 3 intensities (up to 950 mJ) adjusted to usage in
    gastroenterology and urology
  • Very fast
    pulses, sharply rising amplitudes for most effective stone fragmentation
  • Automatic
    pulse frequency (10-40 Hz)
  • Automatic
    probe type recognition
  • Automatic
    probe depletion recognition
  • Single and
    continuous pulses controlled by footswitch
  • Probes are
    highly flexible but keep their position
  • Precisely
    worked probe tip for reproduceable shock waves
  • Rounded probe
    tips help insertion in endoscope and protect the endoscope
  • Centred plasma
    helps maintain distance to tissue (advantage bipolar over coaxial electrodes)


  • Special probes
    for gastroenterology for use with any cholangioscope or Ultraslim gastroscope
    (endoscopic retrograde cholangiopancreatography, ERCP)


Contact the Industry Partner